Coastal luxury villa, Ermioni in Ermioni, Argolid
All case studies
Argolid Coast Properties

Coastal luxury villa, Ermioni

Kranidi Bay Road, 21051 Ermioni, Argolid, Greece

€1,650,000

New-build Ermioni villa in pine woodland above a sheltered bay. Envelope and heat pump are already efficient, so generation, storage and storm resilience carry the whole business case.

Living area
260 m²
Rooms
6
Built
2021
Occupants modelled
4
Heating
Heat pump
Region
Argolid / Peloponnese

Site & energy profile — Argolid / Peloponnese

Solar conditions

  • South-east pitched roof, light pine shading
  • 125 m² usable roof area
  • 1,600 kWh/kWp regional yield · 7% shading derate
  • Modelled at 1,488 kWh/kWp → 30,950 kWh/yr from 20.8 kWp

Load drivers

  • Overflow pool above the bay with year-round filtration
  • Heat pump comfort across a well-insulated 2021 envelope
  • EV charged for the drive between Athens and Ermioni
  • Pressure pumps for the hillside water supply

Resilience context

Coastal Peloponnese feeder — storm-related and seasonal-load outages.

Coastal Argolid feeder sees occasional winter-storm interruptions; whole-home backup covers pool plant, water pressure and comfort without full islanding.

Indicative storage for this profile: 16 kWh.

Pool
EV charging
Three-phase supply
Heat pump

Home Energy IQ summary

Home Energy IQ score

Kranidi Bay Road, Ermioni, Argolid

Argolid / Peloponnese · 1,488 kWh/kWp modelled yield

A

Energy demand

42 kWh/m²a

Running cost

€4,413/yr

CO₂ footprint

8.96 t/yr

A+
A
B
C
D
E
F
G
H

Potential after retrofit

A40 kWh/m²a

Indicative annual saving

€3,831

Highest-impact next step

Rooftop solar PV

€4,636/yr saved · payback 6.5 yrs

Recommended Home Energy IQ system

VILLA ENERGY 30from €31,900 + VAT

Property size of 260 sqm exceeds the HOME 10 envelope.

Modelled retrofit plan

Modelled for this Argolid / Peloponnese property at 1,488 kWh/kWp, with a €45,000 indicative budget and a bill-savings objective. Adjust the assumptions in the simulator to model your own scenario.

Annual saving

€3,831

Net investment

€33,860

incl. €600 subsidies

Simple payback

8.8 yrs

CO₂ avoided

7.67 t/yr

VILLA ENERGY 30 reference installation

Your recommended Home Energy IQ configuration

VILLA ENERGY 30

Premium Independence

Why this fits your property

  • A 260 m² property using about 21,322 kWh of electricity a year sits inside the VILLA ENERGY 30 band (20,000–45,000 kWh/year).
  • Your roof in Argolid / Peloponnese supports roughly 22,320 kWh of production a year, which the 15 kW inverter and 30–32 kWh battery are sized to use rather than export.
  • A heat pump, pool circulation and EV charging push the evening load up, so storage is sized above the entry system.

Projected solar production

22,320 kWh/yr

15 kWp · 1,488 kWh/kWp in Argolid / Peloponnese

Self-powered

78%

Catalogue range 65–85%

Estimated backup

12 h

Essential comfort loads at ≈2 kW

Indicative investment

from €31,900

≈ €337/month over 10 years, excl. VAT

All figures are indicative model estimates for comparison, based on the details you entered. Production, self-powered share and backup duration depend on real weather, occupancy and tariffs. Nothing here is a quotation or a guaranteed performance figure.

Included in this configuration

Solar PV
15 kWp
Hybrid inverter
15 kW three-phase
Battery
30–32 kWh LFP
Backup
Whole Home
  • Whole-home automatic backup
  • Smart Energy Gateway
  • Dynamic zero export
  • Home Energy IQ Advanced
  • Solar forecasting
  • Battery optimisation
Configure your system

Indicative installed price. Final pricing is subject to property survey, electrical infrastructure, grid connection, roof conditions and final engineering design.

Step 3 · Configure upgrades

Optional improvements

Your system works without any of these. They are shown because something in your inputs suggests they could be worth discussing at the assessment.

EV CHARGE

From €1,490

Charges the car on surplus solar instead of peak-tariff grid power — typically €300–€600 a year on the mileage assumed here.

You reported an electric vehicle.

Charge power and savings depend on your vehicle, tariff and daily driving pattern.

V2H READY

Priced at technical assessment

Prepares the electrical architecture so the vehicle could later support the house during an outage.

Only worth adding while the installation is being designed — retrofitting is more disruptive.

Actual vehicle-to-home operation depends on vehicle compatibility and applicable regulation.

SMART VILLA

€1,500–€2,500

Adds circuit-level metering and automatic load shifting, so the pool pump, heat pump and boiler run on solar rather than at night.

A pool pump is one of the largest shiftable loads on this property.

Circuit visibility requires CT clamps at the distribution board; without them, circuit values are estimated.

ENERGY CARE

From €29/month

Continuous monitoring, alerts and an annual performance review so underperformance is caught early rather than at year end.

Recommended for every installation; can be added or dropped later.

A recurring service subscription, separate from the installed system price.

Step 4 · Payment options

€303.11/month

10% deposit (€3,190) · 10 years · 4.90% p.a. illustrative rate

Modelled energy saving

€319.25/month

Net +€16.14/month

Illustrative repayment estimate only — not a credit offer, quotation or approval. It assumes an indicative 4.90% annual rate, equal monthly instalments and the indicative system price before VAT and any subsidy. Actual terms depend on the lender, your circumstances and the final assessed price.

Step 5 · Confirm with an assessment

Confirm your Home Energy IQ plan

A site assessment validates roof and mounting, the electrical panel and connection, permitting requirements and the final price. Everything above stays an indicative model until an engineer has seen the property.

Your plan so far

  • · Recommended system: VILLA ENERGY 30 (Premium Independence) — from €31,900 excl. VAT, indicative
  • · Property profile: Argolid / Peloponnese · 15 kWp modelled at 1,488 kWh/kWp
  • · Modelled outcomes: 22,320 kWh/yr solar · 78% self-powered · ≈12 h backup (Essential comfort loads)
  • · Options to discuss: base configuration only
  • · Financing interest: not reviewed yet

Indicative estimate only. Not a certified energy audit or financial advice.

Prefer to read first? Detailed financing calculator · How assessments work

Today

A

42 kWh/m²a

€4,413/yr · 8,955 kg CO₂

After recommended plan

A

40 kWh/m²a

€582/yr · 1,285 kg CO₂

Projected class movement

A+
A
B
C
D
E
F
G
H

Cumulative saving over 10 years (with 3% annual energy price inflation): €43,918

What your recommended system delivers

Every line below is delivered by VILLA ENERGY 30 or one of its optional Home Energy IQ modules — ranked by impact per euro against your goal and budget.

1

Rooftop solar PV

Solar

Generates power at roughly a third of grid price for 25+ years.

Delivered by your recommended Home Energy IQ system

Net cost
€30,160
Saving/yr
€4,636
Payback
6.5 y
2

Smart energy manager & hydronic balancing

Smart & control
€600 subsidy

Cheapest measure per euro saved and the data layer for everything that follows.

Optional add-on: SMART VILLA module

Net cost
€1,800
Saving/yr
€131
Payback
13.7 y
3

Smart EV charger (11 kW)

E-mobility

Charges on surplus solar instead of peak-tariff grid power.

Optional add-on: EV CHARGE module

Net cost
€1,900
Saving/yr
€74
Payback
25.7 y

Catalogue options outside your budget

Home battery storage

Storage

Shifts midday solar into evening use and raises self-consumption to ~70%.

Delivered by your recommended Home Energy IQ system

Net cost
€14,920
Saving/yr
€806
Payback
18.5 y

All figures shown are indicative estimates generated from standardised building models and average market prices. They are not a certified energy performance assessment, an engineering report, or financial advice. Actual savings, costs, subsidies and payback depend on an on-site assessment of your property.

Customise in the simulatorModel the financingBook an assessment

All figures shown are indicative estimates generated from standardised building models and average market prices. They are not a certified energy performance assessment, an engineering report, or financial advice. Actual savings, costs, subsidies and payback depend on an on-site assessment of your property.